Three Phase Induction Motors

Saturday - 17/02/2018 02:24

Three Phase Induction Motors

Three phase induction motors have been a popular choice for many industrial applications for a number of reasons: Non-complex construction – they don’t require permanent magnets, brushes or windings on the rotor

They run directly off of the electric distribution grid

Low cost

Motor B35

Rugged and suitable for hazardous environments

Due to not having brushes, they are long lasting and require minimal maintenance

However, one of the main drawbacks of the 3 phase induction motor is that they have a small, load-dependent speed range. This limits the types of applications induction motors can be used for.

But what causes this to be a drawback for induction motors?

The synchronous speed of induction motors is dependent on the number of poles of the motor and the frequency of the supply power. Simply put

dolin machines(hp)

Formula

where ns is the synchronous speed, f is the supply frequency and p is the number of motor poles. The actual motor speed will then be slightly less than the synchronous speed and will be dependent on the motor load.

For a given motor, the number of poles is fixed so the only way to change speeds is to change the frequency of the power supply to the motor. Because electrical grids run at a fixed frequency, induction motors generally run at a constant speed, with only slight variation as the load changes.

A variety of methods have been developed for speed control of AC induction motors but one of the most cost effective ones is the open loop, “V/f” control.

dolinmotors

The ratio of voltage to frequency (or V/f) is used because the flux in the air gap of an induction motor is proportional to V/f. So in order to maintain constant flux, the V/f control will change the voltage proportionally to the frequency.

For example, a 230 V, 60 Hz motor has a V/f ratio of 3.83. If it is a 2 pole motor, its synchronous speed is 3600 RPM. In order to cut the synchronous speed in half to 1800 RPM, the control would supply 115 V, 30 Hz, which maintains the V/f ratio of 3.83.

gear reducer box


 

This method of control still allows slight variations of speed due to changing motor loads. Some control manufacturers fix this problem by using a slip compensation feature, which basically estimates how the load effects speed and then increases the power supply frequency to provide even better speed regulation.

 